The CTS-PA22B JW Rim Axle phased array ultrasonic detector is a portable phased array ultrasonic testing instrument which is newly developed by Goworld with up to 64 detection channels.
The CTS-PA22B JW Rim Axle phased array ultrasonic detector is a portable phased array ultrasonic testing instrument which is newly developed by Goworld with up to 64 detection channels. Its manufacturing and testing comply with international industrial standard (ISO) and international electrical standard (IEC). All measurement units adopt international unit standard system (SI).It is a professional phased array ultrasonic flaw detector specially designed for the inspection of railway rims. The instrument is operated in Chinese-English with waterproof and oil-proof panel and fan-free design. It is simple and fast to operate and achieves full record of testing data. It is an advanced intelligent PA ultrasonic flaw detector. The instrument is equipped with a special detection channel for rims, which can realize the storage and transfer of channel parameters and the function of rapid detection for rims.
16: 64 configuration & 2 conventional detection, to meet the various detection needs of customers.
Modular design of software function, separated rim inspection, process and file management, to realize the division and cooperation of inspection work.
The 3D modeling scheme, customizable for one-stop solutions.
Equipped with special phased array probe and rim automatic crawler to realize automatic and rapid PA detection of locomotive rim.
Equipped with a system-controlled trolley to realize automatic supply of couplant, convenient and efficient on-site detection.
Two sets of conventional detection channels, providing 4 probe interfaces to meet the needs of various detection occasions.
Host internal memory: 1GB memory + 4GB FLASH; expand 32GSD card, fast and efficient data processing.
Built in GPS module for precise positioning.
Image smoothing, for finer presentation.
Dynamic depth-focusing, for high discernibility at different depths.
Delay precision up to 1ns, for evident inhibition on sidelobes so as to enhance vertical and horizontal discernibility, as well as to improve imaging definition.
Supportive of ACG and TCG curves, to solve the problem of uneven energy distribution and poor measurement accuracy.
The detection image can be magnified and moved at will to realize the detailed observation and fine measurement of defects.
Touch screen operation can realize the linkage between the gate and the sound beam angle, and quickly measure the defects and display the results.
HDMI video interface realizes the expansion and amplification of detection image in HD.
Automatic generation of focal laws according to beam angle, focal length, scan mode, specs of probe and wedge, with optimized angle stepping of S-scan.
Conventional A-scan, PA A/L/S/C scan imaging; Encoder used for continuity of 100%-original-data logging.
3 options of filtering: 0.5-9.7MHz、4.0-12.5MHz、6.7-20.8MHz; Auto Optimization of pulse width according to probe frequency; Excellent noise filtration.
11-inch IG & WVGA (800x600) TFT display, touch screen, ensuring nice visual effect outdoors or in the sun.
AC/DC optional, can be powered by lithium battery, can work for 6+ hrs of continuous service
With the technical evaluation certificate of scientific and technological achievements issued by the Railway Bureau.
Channel Configuration | |
PA | 16:64 |
UT | 2 |
Physical Specification | |
Display | 11-inch 800X600 TFT color display |
Transducer Ports | I-PEX 160-pin PA transducer port; Lemo-00 conventional transducer Port, for either T-R or T&R |
I/O Ports | USB2.0 Port: 2(qty);HDMI;LAN;WIFI; I/O;2D Encoder |
Memory | In-Built: 16G RAM+4GB FLASH ;SD card (max to 32G); External: USB drive |
Weight | 3.5kg(with 1 battery) |
Dimension | 284mm×202mm×95mm |
Power Supply | AC:100~240V,50~60Hz;DC:12V |
Charging | (battery) within or individually |
Battery Life | 6 Hours |
Working Power | 26W |
Language | English |
Temperature | Ambiance:-20℃~50℃ |
IP | IP54 |
Performance Specification: PA | |
PRF | 50Hz~ 10kHz |
Voltage | Bipolar,±45V~±100V,with 5V per step |
Pulse Width | 20ns~800ns,with 5ns per step |
Damping | 50Ω |
Sampling Rate | 100MHz |
Delay Precision | 1ns |
Rx Delay | 0us~ 40us |
Bandwidth | 0.5MHz~ 20.8MHz |
Gain | 0.0dB~ 80dB |
Filter | 0.5-9.7MHz, 4.0-12.5MHz, 6.7-20.8MHz Optional |
Rectification | FW |
Scan Line | Max 128 |
Triggering | Encoder, Time-based |
Scan Mode | L/S/C -scan |
Skew | -89°~ +89° |
Auto-Cal | Velocity,Delay,TCG,ACG,Encoder |
Range | 0.0~1000mm,min 11mm |
Displaying Delay(Max) | 1000mm |
Unit | mm |
Gate | A、B |
Gate Start | Available within the range |
Gate Width | Available within the range |
Gate Threshold | 0%~ 100% |
Alarming | Buzzer / LED |
Spotting | Crest/Flank |
Readout | Amp/Path/Horizontal/Depth |
Resolution | 0.5mm |
Performance Specification: UT | |
PRF | 50Hz~ 5kHz |
Voltage | Negative Square Wave,-75V~-250V,with 25V per step |
Pulse Width | 20~800ns,with 5ns per step |
Damping | 80Ω/400Ω |
Sampling Rate | 200MHz |
Bandwidth | 0.5MHz~ 15MHz |
Gain | 0.0dB~ 110.0dB |
Filter | Broadband, Narrowband |
Rectification | FW,Positive,Negative, RF |
Triggering | Time-based |
Scan Mode | A scan, Consecutive Storage |
A scan, Consecutive Storage | Velocity,Delay,X-Value,DAC, DGS |
Range | 0.0~2000mm,min 1mm |
Displaying Delay(Max) | 2000mm |
Pulse Shift(max) | 2000mm |
Unit | mm |
Gate | A、B |
Gate Start | Available within the range |
Gate Width | Available within the range |
Gate Threshold | 0%~ 100% |
Alarming | Buzzer / LED |
Spotting | Crest/Flank |
Readout | Amp/Path/Horizontal/Depth |
Resolution | 0.1mm |