The SCQtofd-5 scanner is designed with T-shaped structure and the mounting position of the T-shaped junction can be moved freely suitable for inspection of plate welds or curved welds of work piece with small curvature.
The SCQtofd-5 scanner is designed with T-shaped structure and the mounting position of the T-shaped junction can be moved freely suitable for inspection of plate welds or curved welds of work piece with small curvature.
Fixed integral T-shaped structure ensures stable and constant.
Mounting position of the T-shaped junction can be moved freely suitable for scanning the special structure welds.
Three magnetic wheels can absorb the whole scanner to a work piece surface.
Mounting holder frame bar with a PCS adjustment scale allows forward and reverse mounting holders for easy PCS value adjustment.
PCS Stretch | Combined with TOFD wedges (front edge: 8mm) manufactured by Goworld and the PCS adjustment range of 20mm~350mm (user customizable). |
Encoder Accuracy | 5 step/mm |
Encoder Interface | Industry-standard encoder interface complies with the new rules and other TOFD testing standards. |
I. Single channel TOFD or two-channel PE inspection.
II. Non-parallel scanning can be performed.
III. Suitable for inspecting large thickness welds with small curvature needed for simultaneous subfield scanning.
IV. Combined with CTS-2009 or CTS-1008plus ultrasonic flaw detector.